Inhaltsverzeichnis

Seite 1 - 5-Gas Analyzer

116 & 16P Operator’s Manual5-Gas Analyzer

Seite 2 - Table of Contents

10Engine SetupMain Menu ScreenFrom the Main Menu, use the SELECT buttons to move the arrow up to Analyzer & Engine Setups then press the NEXT butt

Seite 3 - Specifications

11RPM SourceUse the SELECT buttons to choose the RPM source, then press the NEXT button. You will be returned to the analyzer setup screen. Selectin

Seite 4 - Buttons & Controls

12Report PrintingFrom the Main Menu, use the SELECT buttons to move the selec-tion arrow to REPORT then press the NEXT button. The following screen w

Seite 5 - Connecting to the Vehicle

13Maintenance - Zero & PurgeZero Use the SELECT buttons to move the selection arrow to select one of the Calibration and Maintenance program. Whe

Seite 6 - Start-Up & Warm-Up

14Maintenance - CalibrateThe calibrate program is used to gas calibrate the analyzer. Gas calibration should be performed monthly. This procedure wi

Seite 7

15The analyzer will zero the gas bench then ask you to turn on the gas valve on and adjust the pressure regulator until the bar graph is between the t

Seite 8 - Analyzer Setups

16Record & PlaybackYou may press the REC/PAUSE/PLAY button any time you are measuring emissions. If you are using the Big Digit display,

Seite 9

17Gas TheoryThe content of an engine’s exhaust stream depends on the efficiency of the combustion process. Ideally, pure fuel (hydrogen and carbon) an

Seite 10 - Engine Setup

18Gas TheoryAFR (Air Fuel Ratio), Lambda and StoichiometryStoichiometry is where air and fuel are in the proportions that provide the greatest co

Seite 11

19Gas TheoryCarbon Monoxide (CO)Carbon monoxide is formed when there is not enough oxygen to support combustion. Fuel system problems are the usual c

Seite 12 - Report Printing

2Table of ContentsIntroduction ... 4Specifications ...

Seite 13

20Routine MaintenanceLow Flow MessageThe low flow message can be caused by clogged or dirty filters, excessive water moisture in the filters, or an extre

Seite 14 - Maintenance - Calibrate

21WarrantyFERRET BRAND LIMITED PRODUCT WARRANTYGxT, Inc. of Cheboygan Michigan, warrants to the original purchaser that FERRET brand products are free

Seite 15 - Internal Batteries

22SAFETY PRECAUTIONS—Read All Instructions Before Using The Meter—• Always wear eye protection when testing vehicles. Be extra careful near batteries

Seite 17 - Gas Theory

24Copyright © 2006 GxT, Inc. Cheboygan Michigan, USAE016-01

Seite 18

3SpecificationsMeasurement RangesHydrocarbons (HC) ...0 to 15,000 ppmCarbon Monoxide (CO) ...

Seite 19

4IntroductionThe GasLink II™ is the ultimate in portable gas analyzers. Small and portable, it can easily be taken on road tests and stored in a too

Seite 20 - Routine Maintenance

5Connecting to the VehicleBattery Power LeadsConnect the RED lead to the Battery Positive, and the BLACK lead to Battery Negative post. The anal

Seite 21 - Warranty

6Start-Up & Warm-UpWhen power is applied to the unit, the start-up screen appears for a few seconds. This screen shows the date of the last gas c

Seite 22 - SAFETY PRECAUTIONS

7Big Digit ScreenPress either the Up or Down select buttons to alternate between the composite, Grams per Mile and Big Digit screens. The big digit

Seite 23

8Analyzer SetupsAnalyzer Setup ScreenUse the SELECT buttons to move the selection arrow to Analyzer Setup then press the NEXT button. The following s

Seite 24

9Program a Custom HeaderUp to four lines of header information can be entered. The header is created in the top two lines of the screen. The bottom tw